DTC P0603

- Control Module Long Term Memory Reset

DTC P0604

- Control Module Random Access Memory (RAM)

DTC P062F

- Control Module Long Term Memory Performance

Circuit/System Description

This is an internal fault detection of the control solenoid valve assembly. This fault is carried out inside the control solenoid valve assembly and no

external circuits are involved.

Conditions for Running the DTC

* DTCs P0601, P0602, P0603, P0604, or P062F are not set.

* Ignition voltage is 8.6 volts or greater.

Conditions for Setting the DTC

P0601

The read only memory (ROM) test has failed 5 or more times.

P0602

The transmission control module (TCM) has not been programmed.

P0603

The TCM has detected a memory checksum error.

P0604

The TCM random access memory (RAM) test has failed 5 or more times.

P062F

The TCM has detected non-volatile memory is incorrect during power-down.

Action Taken When the DTC Sets

* DTCs P0601, P0602, P0603, P0604, and P062F are Type A DTCs.

* The TCM shifts to a default gear, shuts down, and turns OFF.

Conditions for Clearing the DTC

DTCs P0601, P0602, P0603, P0604, and P062F are Type A DTCs.

Reference Information

Description and Operation

Electronic Component Description (See: Transmission and Drivetrain/Automatic Transmission/Transaxle/Description and

Operation/6L45/6L50/6L80/6L90 - Automatic Transmission/Electronic Component Description)

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions (See: Diagnostic Trouble Code Descriptions/Powertrain Diagnostic Trouble Code

(DTC) Type Definitions)

Circuit/System Verification

1. Ignition OFF for one minute.

Caution: Before programming a control module, the following must be observed, or control module damage may occur:

* The scan tool and the terminal must have the latest software.

* The vehicle battery must be fully charged. The battery voltage should be between 12-14 volts.

* The scan tool and the terminal cable connections must be secure.