DTC Descriptor

DTC P0BE6

- Drive Motor 1 Phase U Current Sensor Performance

DTC P0BE7

- Drive Motor 1 Phase U Current Sensor Circuit Low Voltage

DTC P0BE8

- Drive Motor 1 Phase U Current Sensor Circuit High Voltage

DTC P0BEA

- Drive Motor 1 Phase V Current Sensor Performance

DTC P0BEB

- Drive Motor 1 Phase V Current Sensor Circuit Low Voltage

DTC P0BEC

- Drive Motor 1 Phase V Current Sensor Circuit High Voltage

DTC P0BEE

- Drive Motor 1 Phase W Current Sensor Performance

DTC P0BEF

- Drive Motor 1 Phase W Current Sensor Circuit Low Voltage

DTC P0BF0

- Drive Motor 1 Phase W Current Sensor Circuit High Voltage

DTC P0BF2

- Drive Motor 2 Phase U Current Sensor Performance

DTC P0BF3

- Drive Motor 2 Phase U Current Sensor Circuit Low Voltage

DTC P0BF4

- Drive Motor 2 Phase U Current Sensor Circuit High Voltage

DTC P0BF6

- Drive Motor 2 Phase V Current Sensor Performance

DTC P0BF7

- Drive Motor 2 Phase V Current Sensor Circuit Low Voltage

DTC P0BF8

- Drive Motor 2 Phase V Current Sensor Circuit High Voltage

DTC P0BFA

- Drive Motor 2 Phase W Current Sensor Performance

DTC P0BFB

- Drive Motor 2 Phase W Current Sensor Circuit Low Voltage

DTC P0BFC

- Drive Motor 2 Phase W Current Sensor Circuit High Voltage

Circuit/System Description

This is an internal fault detection of the drive motor generator power inverter module (PIM) assembly. This fault is handled inside the PIM and no

external circuits are involved.

Conditions for Running the DTC